EDS-316 Series

Features and Benefits

Overview

The EDS-316 Ethernet switches provide an economical solution for your industrial Ethernet connections. These 16-port switches come with a built-in relay warning function that alerts network engineers when power failures or port breaks occur. In addition, the switches are designed for harsh industrial environments, such as the hazardous locations defined by the Class I Div. 2 and ATEX Zone 2 standards.

The switches comply with FCC, UL, and CE standards and support either a standard operating temperature range of -10 to 60°C or a wide operating temperature range of -40 to 75°C. All switches in the series undergo a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. The EDS-316 switches can be installed easily on a DIN rail or in a distribution box.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)

  • EDS-316 models: 16
  • EDS-316-MM-SC/MM-ST/MS-SC/SS-SC models: 14
  • EDS-316-SS-SC-80 models: 14
  • EDS-316-M-SC/M-ST/S-SC models: 15

    All models support:
  • Auto negotiation speed
  • Full/Half duplex mode
  • Auto MDI/MDI-X connection

100BaseFX Ports (multi-mode SC connector)

  • EDS-316-M-SC models: 1
  • EDS-316-MM-SC models: 2
  • EDS-316-MS-SC models: 1

100BaseFX Ports (multi-mode ST connector)

  • EDS-316-M-ST models: 1
  • EDS-316-MM-ST models: 2

100BaseFX Ports (single-mode SC connector)

  • EDS-316-MS-SC models: 1
  • EDS-316-S-SC models: 1
  • EDS-316-SS-SC models: 2

100BaseFX Ports (single-mode SC connector, 80 km)

  • EDS-316-SS-SC-80 models: 2

Standards

  • IEEE 802.3 for 10BaseT
  • IEEE 802.3u for 100BaseT(X) and 100BaseFX
  • IEEE 802.3x for flow control

Processing Type

  • Store and Forward

MAC Table Size

  • 4 K

Packet Buffer Size

  • 1.25 Mbits

Alarm Contact Channels

  • 1 relay output with current carrying capacity of 1 A @ 24 VDC

Ethernet Interface

  • Port break alarm

Connection

  • 1 removable 6-contact terminal block(s)

Input Voltage

  • 12/24/48 VDC
    Redundant dual inputs

Operating Voltage

  • 9.6 to 60 VDC

Input Current

  • 0.34 A (EDS-316) @ 24 VDC
  • 0.35 A (EDS-316-S-SC) @ 24 VDC
  • 0.35 A (EDS-316-M-SC, EDS-316-M-ST) @ 24 VDC
  • 0.40 A (EDS-316-SS-SC) @ 24 VDC
  • 0.39 A (EDS-316-MM-SC, EDS-316-MM-ST) @ 24 VDC

Reverse Polarity Protection

  • Supported

Overload Current Protection

  • Supported

Dimensions

  • 80.1 x 135 x 105 mm (3.15 x 5.31 x 4.13 in)

Installation

  • DIN-rail mounting
  • Wall mounting (with optional kit)

Housing

  • Metal

Weight

  • 1140 g (2.52 lb)

IP Rating

  • IP30

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

Operating Temperature

  • Standard Models: -10 to 60°C (14 to 140°F)
  • Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature (package included)

  • -40 to 85°C (-40 to 185°F)

Safety

  • EN 62368-1
  • UL 508
  • UL 60950-1
  • CSA C22.2 No. 60950-1

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m
  • IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
  • IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
  • IEC 61000-4-6 CS: 10 V
  • IEC 61000-4-8 PFMF

Hazardous Locations

  • ATEX
  • Class I Division 2

Shock

  • IEC 60068-2-27

Vibration

  • IEC 60068-2-6

Freefall

  • IEC 60068-2-32

Maritime

  • DNV

Time

  • EDS-316 models: 2,226,219 hrs
  • EDS-316-MM/MS/SS models: 1,904,659 hrs
  • EDS-316-M/S models: 2,048,802 hrs

Standards

  • MIL-HDBK-217F

Warranty Period

  • 5 years