Delta Micro Data Center

Features and Benefits

Overview

Delta InfraSuite is a new generation, highly integrated modular datacenter solution. It uses racks as the datacenter carrier and fully integrates all sub-systems including UPSs, cooling, power distribution, lightning protection, fire control (optional), wiring, airflow management, intelligent monitoring, and more. Delta’s modular datacenter solution offers a datacenter environment that provides safe equipment operations within the racks, and supports the development and standardizing of micro datacenters that fit into racks. In addition, Delta InfraSuite takes up very little space, allowing quick deployment within a limited space, and it provides 10 types of solutions that require 20kVA power supply capabilities.

Specifications

Vari°Row ® Configurable Micro-datacenter

Delta microdatacentre is designed and engineered with expansion in mind. It allows IT
professionals to smoothly, plan, grow and manage critical assets as they expand their

infrastructure. Cabinet 1 contains power input, UPS batteries, DB and HMI.

Expandable Monitoring

  • Fully integrated 10” HMI

Modular Cooling

  • Scalable rack and row cooling

Modular Power

  • RT 3kVA20KVA UPS

Modular Cabinet

  • Door containment to maintain HACS

Basic Nconfiguration

  • Single UPS from 3kVA up to 30kVA.
  • Single Row Cooling 5.6kW up to 30kW.
  • Single PDU with bypass function.

N+1 or 2Nconfiguration

  • Dual UPS from 3kVA up to 30kVA.
  • Dual Row Cooling 5.6kW up to 30kW with N+1 or 2N configuration.
  • Single PDU with N+1 or Dual PDU to support dual feeder configuration.

Model

  • Total Cooling Capacity:
    • HC05R: 5.6
    • HC07R: 7.6
    • HC12R: 12.8
    • HC17R: 17.6
    • HC20R: 21.2
    • HC25R: 25.1
  • SHR%:
    • HC05R: 100
    • HC07R: 100
    • HC12R: 100
    • HC17R: 100
    • HC20R: 100
    • HC25R: 100
  • Air Volume CFM:
    • HC05R: 1177
    • HC07R: 1295
    • HC12R: 1413
    • HC17R: 2650
    • HC20R: 2896
    • HC25R: 2943
  • Power Input:
    • HC05R: 230V/60Hz
    • HC07R: 230V/60Hz
    • HC12R: 400V/60Hz
    • HC17R: 400V/60Hz
    • HC20R: 400V/60Hz
    • HC25R: 400V/60Hz
  • Mounting type:
    • HC05R: Row
    • HC07R: Row
    • HC12R: Row
    • HC17R: Row
    • HC20R: Row
    • HC25R: Row
  • Cooling Type:
    • HC05R: DX
    • HC07R: DX
    • HC12R: DX
    • HC17R: DX
    • HC20R: DX
    • HC25R: DX
  • Heightmm:
    • HC05R: 2000
    • HC07R: 2000
    • HC12R: 2000
    • HC17R: 2000
    • HC20R: 2000
    • HC25R: 2000
  • Depthmm:
    • HC05R: 1100
    • HC07R: 1100
    • HC12R: 1100
    • HC17R: 1100
    • HC20R: 1100
    • HC25R: 1100
  • Widthmm:
    • HC05R: 300
    • HC07R: 300
    • HC12R: 300
    • HC17R: 300
    • HC20R: 300
    • HC25R: 300
  • Weightkg:
    • HC05R: 210
    • HC07R: 213
    • HC12R: 233
    • HC17R: 253
    • HC20R: 258
    • HC25R: 260
  • Reheat (Option)kW:
    • HC05R: 3
    • HC07R: 3
    • HC12R: 3
    • HC17R: 6
    • HC20R: 6
    • HC25R: 6
  • Humidity (Option)kg/h:
    • HC05R: 1.5
    • HC07R: 1.5
    • HC12R: 1.5
    • HC17R: 1.5
    • HC20R: 1.5
    • HC25R: 1.5

Model

  • Power Input:
    • HSF08A: 230V/60Hz
    • HSF12A: 230V/60Hz
    • HSF18A: 400V/60Hz
    • HSF24A: 400V/60Hz
    • HSF32A: 400V/60Hz
    • HSF38A: 400V/60Hz
  • Heightmm:
    • HSF08A: 790
    • HSF12A: 790
    • HSF18A: 1240
    • HSF24A: 689
    • HSF32A: 689
    • HSF38A: 695
  • Depthmm:
    • HSF08A: 480
    • HSF12A: 480
    • HSF18A: 480
    • HSF24A: 990
    • HSF32A: 990
    • HSF38A: 990
  • Widthmm:
    • HSF08A: 800
    • HSF12A: 800
    • HSF18A: 800
    • HSF24A: 1384
    • HSF32A: 1384
    • HSF38A: 1384
  • Leg Heightmm:
    • HSF08A: –
    • HSF12A: –
    • HSF18A: –
    • HSF24A: 450
    • HSF32A: 450
    • HSF38A: 450
  • Weightkg:
    • HSF08A: 28
    • HSF12A: 40
    • HSF18A: 67
    • HSF24A: 105
    • HSF32A: 110
    • HSF38A: 120
*cooling capacity based on 37 ̊C/24%RH return air and 35 ̊C outdoor temperature