EDF-G1002-BP Series

Features and Benefits

Overview

The EDF-G1002-BP Series is an industrial-grade LAN firewall with IPS and DPI functionality to protect mission-critical assets and network zones. These industrial firewalls support software-configurable Gen3 LAN bypass to achieve bump-in-the-wire installation and minimize the installation impact for industrial applications such as ITS, pump-and-treat systems in water stations, distributed control systems in oil and gas, and PLC/SCADA systems in factory automation.

Specifications

Input/Output Interface

Alarm Contact Channels

  • Resistive load: 1 A @ 24 VDC

Buttons

  • Reset button

Digital Input Channels

  • +13 to +30 V for state 1
  • -30 to +3 V for state 0
  • Max. input current: 8 mA

10/100/1000BaseT(X) Ports (RJ45 connector)

  • 3 (2 x LAN ports, 1 x MGMT port)

Standards

  • IEEE 802.3 for 10BaseT
  • IEEE 802.3u for 100BaseT(X)
  • IEEE 802.3ab for 1000BaseT(X)
  • IEEE 802.3x for flow control

LED Indicators

  • PWR1, PWR2, STATE, BYPASS, USB

Technology

  • ARP-Flood
  • FIN Scan
  • ICMP Flood
  • TCP Sessions Without SYN
  • NMAP-ID Scan
  • NMAP-Xmas Scan
  • Null Scan
  • SYN/FIN Scan
  • SYN/RST Scan
  • SYN-Flood
  • Xmas Scan

Throughput

  • Max. 45K packets per second / 500 Mbps (based on RFC 2544)

Filter

  • DDoS
  • Ethernet protocols
  • ICMP
  • IP address
  • MAC address
  • Ports

Intrusion Prevention System

  • Enabled by default. IPS pattern update functionality requires an additional license.

Deep Packet Inspection

  • Modbus TCP
  • Modbus UDP
  • DNP3
  • IEC 60870-5-104
  • IEC 61850 MMS
  • EtherNet/IP
  • Omron FINS
  • Siemens S7 Comm.
  • Additional protocols will be supported through future firmware updates.

Event Type

  • Firewall events
  • Protocol DPI and IDS/IPS events

Media

  • Syslog server
  • Local storage
  • SNMP Trap

Console Port

  • RS-232 (TxD, RxD, GND), 3-pin (115200, n, 8, 1)

Connector

  • USB Type-C

Connection

  • Removable terminal block

Operating Voltage

  • 9.6 to 60 VDC

Input Voltage

  • 12/24/48 VDC
  • Redundant dual inputs

Input Current

  • 0.69 A (max)

Reverse Polarity Protection

  • Supported

Housing

  • Metal

Dimensions

  • 35 x 125 x 100 mm (1.38 x 4.92 x 3.94 in)

Weight

  • 385 g (0.85 lb)

Installation

  • DIN-rail mounting
  • Wall mounting

Operating Temperature

  • Standard Models: -10 to 60°C (14 to 140°F)
  • Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature (package included)

  • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

Safety

  • IEC 62368-1
  • UL 62368-1

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
  • IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
  • IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
  • IEC 61000-4-6 CS: 10 V
  • IEC 61000-4-8 PFMF

Railway

  • EN 50121-4

Traffic Control

  • NEMA TS2

Shock

  • IEC 60068-2-27

Freefall

  • IEC 60068-2-32

Vibration

  • IEC 60068-2-6

Time

  • 2,929,641 hrs

Standards

  • Telcordia (Bellcore)
  • GB

Warranty Period

  • 5 years